Extech 400A Dual Input AC/DC Clamp Meter + NCV
The Extech 400A Dual Input AC/DC Clamp Meter + NCV provides true RMS measurements for accurate AC voltage and current.
Features
- Built-in non-contact Voltage detector with LED alert
- 1.25" (32mm) jaw opening for conductors up to 500MCM
- Autoranging with manual override
- Free ground shipping
- Expedited repair and warranty service
- Lifetime technical support
- More
The Extech 400A AC/DC Clamp Meter + NCV has built-in thermocouple inputs for T1, T2, and T1-T2 differential temperature measurement. The 40,000 count multimeter has functions for DC voltage, resistance, capacitance, and frequency for high resolution over wider ranges.The true RMS measurements are conducted for accurate AC voltage and current. The meter also features a built-in non-contact voltage detector with LED alert. The 1.25" jaw opening fits conductors up to 500MCM.
Models EX622 and EX623 feature an additional built-in non-contact IR thermometer with laser pointer for locating hot spots at an 8 to 1 distance to target ratio. Models EX613 and EX623 also include a DC current function ideal for automotive, heavy equipment, and marine applications.
EX613
- AC current: 400.0A
- DC current: 400.0A
- Maximum resolution: 10mA
- Basic ACA accuracy: ±1.5%
- AC/DC voltage maximum resolution: 600V (0.1mV)/600V (0.01mV)
- DC μA current: 4000μA (0.01μA)
- Resistance maximum resolution: 40.000MΩ (0.01)
- Capacitance maximum resolution: 10pF to 40,000μF (0.01nF)
- Frequency maximum resolution: 40MHz (0.001Hz)
- Temperature type K: -58 to 1832°F (-50 to 1000°C)
- Diode test: < 2.8V
- Duty cycle: 0.5 to 99.0%
- Dimensions: 9x3.1x1.9" (229x80x49mm)
- Weight: 10.7oz (303g)
EX622
- Temperature IR: -58 to 518°F (-50 to 270°C)
- AC current: 400.0A
- Maximum resolution: 10mA
- Basic ACA accuracy: ±1.5%
- AC/DC voltage maximum resolution: 600V (0.1mV)/600V (0.01mV)
- DC μA current: 4000μA (0.01μA)
- Resistance maximum resolution: 40.000MΩ (0.01)
- Capacitance maximum resolution: 10pF to 40,000μF (0.01nF)
- Frequency maximum resolution: 40MHz (0.001Hz)
- Temperature type K: -58 to 1832°F (-50 to 1000°C)
- Diode test: < 2.8V
- Duty cycle: 0.5 to 99.0%
- Dimensions: 9x3.1x1.9" (229x80x49mm)
- Weight: 10.7oz (303g)
EX623
- Temperature IR: -58 to 518°F (-50 to 270°C)
- AC current: 400.0A
- DC current: 400.0A
- Maximum resolution: 10mA
- Basic ACA accuracy: ±1.5%
- AC/DC voltage maximum resolution: 600V (0.1mV)/600V (0.01mV)
- DC μA current: 4000μA (0.01μA)
- Resistance maximum resolution: 40.000MΩ (0.01)
- Capacitance maximum resolution: 10pF to 40,000μF (0.01nF)
- Frequency maximum resolution: 40MHz (0.001Hz)
- Temperature type K: -58 to 1832°F (-50 to 1000°C)
- Diode test: < 2.8V
- Duty cycle: 0.5 to 99.0%
- Dimensions: 9x3.1x1.9" (229x80x49mm)
- Weight: 10.7oz (303g)
- (1) Meter
- (1) Set of CAT III-600V double molded test leads
- (1) 9V battery
- (2) Type K bead wire probes
- (1) Case
In The News
Climate Change and Microplastics: Monitoring Lake Champlain
Most people go to Lake Champlain for its exceptional views and thrilling boating, but it’s also home to a wide variety of interesting aquatic research projects. From studying microplastics to thermal dynamics of the lake, Timothy Mihuc, director of the Lake Champlain Research Institute (LCRI) at the State University of New York at Plattsburgh (SUNY Plattsburgh), has spent his career studying aquatic ecosystems. 
 
 As an aquatic biologist, he’s the main investigator on Lake Champlain’s research studies while also managing their grants, employees, and their hands-on buoy work. 
 
 Over the years, LCRI has received a number of environmental grants that aid in its monitoring research.
Read MoreCurrent Monitoring after the Francis Scott Key Bridge Collapse
On March 26th, according to The Baltimore Sun , a 984-foot, 112,000-ton Dali lost propulsion and collided with a support column of the Francis Scott Key Bridge, collapsing the structure. Soon after the event, search and rescue, salvage crews, and other emergency responders were mobilized after the collision. 
 
As salvage efforts progressed in early April, NOAA’s Center for Operational Oceanographic Products and Services (CO-OPS) responded to a request for real-time tidal currents data and deployed a current monitoring buoy—CURBY (Currents Real-time BuoY)—into the Patapsco River north of the Francis Scott Key Bridge.
Read MoreSoundscapes of the Solar Eclipse: Citizen Science Supporting National Research
On April 8, 2024, millions of people around the world had their eyes glued to the sky to witness a historic cosmic event. The total solar eclipse captured the headlines and the minds of many who became eager to gaze at the heavens as the sky went dark for a few minutes. However, not everyone used their sense of sight during the eclipse, some were listening to the sounds of the natural world around them as the light faded from above. 
 
 The Eclipse Soundscape Project is a NASA-funded citizen science project that focuses on studying how the annular solar eclipse on October 14, 2023, and the April 8, 2024 total solar eclipse impacted life on Earth. 
 
 The project revisits an initiative from the 1930s that showed animals and insects are affected by solar eclipses.
Read More